CSS I/O 7
I - 1 Execution of Switching Functions
In PULSED mode, the relay is activated (ON or OFF) for a specific
period of time. After the period has timed out, the relay is deactivated.
The pulse time is 0.1 to 999 seconds.
Continuous mode shown:
Pulsed mode shown:
The time period begins whenever the switching condition
transitions from FALSE to TRUE. If the switching conditions
transitions to TRUE before the period has timed out, the
timer will start over.
The switching functions cannot be used for coupled axes or
for axes with backlash compensation.
Relay
Condition
Relay
Condition